About this item
The Titronic® 300 is a motor-driven burette for manual titration and and a precise dosing instrument for dispensable liquids, solvents and titrating agents. It can be used as a stand-alone instrument but it can also function as a titration and dosing burette in computer-controlled (automatic) titrating systems. Ideal for labs where high precision and flexibility are required.
Manual titration with hand controller (mouse):
Titration rate can be adjusted in five different steps to optimise titration speed and accuracy
Automatic calculation of results in different units and documentation on a printer or USB memory device
Automatic weight recording when balance is connected
Dosing:
Adjustable dosing and filling rate for each method; adjustable filling between each dose step
Intelligent filling function checks in advance if a dosing step is feasible: Reduces faulty operations during a serial dosing process
Specifications
- Catalog No:
- 661-0219
- 661-0220
- 661-0218
- 661-0217
- Model:
- Titronic® 300
- Titronic® 300
- Titronic® 300
- Titronic® 300
- Display:
- Graphical TFT
- Graphical TFT
- Graphical TFT
- Graphical TFT
- Display resolution:
- 0,005 - 0,025 ml (depending on dosing unit)
- 0,005 - 0,025 ml (depending on dosing unit)
- 0,005 - 0,025 ml (depending on dosing unit)
- 0,005 - 0,025 ml (depending on dosing unit)
- Volume display:
- 0000,000...9999,999 ml
- 0000,000...9999,999 ml
- 0000,000...9999,999 ml
- 0000,000...9999,999 ml
- Keypad:
- Optional USB keyboard (TZ 3835) can be connected
- Optional USB keyboard (TZ 3835) can be connected
- Optional USB keyboard (TZ 3835) can be connected
- Optional USB keyboard (TZ 3835) can be connected
- Stirrer connection:
- Connection for stirrer TM 50
- Connection for stirrer TM 50
- Connection for stirrer TM 50
- Connection for stirrer TM 50
- Dosing accuracy:
- 0,15% (systematic error); 0,05% (random error)
- 0,15% (systematic error); 0,05% (random error)
- 0,15% (systematic error); 0,05% (random error)
- 0,15% (systematic error); 0,05% (random error)
- Dosing volume:
- 20/50 ml
- 20/50 ml
- 20/50 ml
- 20/50 ml
- Dosing speed:
- Max. 100 ml/min (with 50 ml unit)
- Max. 100 ml/min (with 50 ml unit)
- Max. 100 ml/min (with 50 ml unit)
- Max. 100 ml/min (with 50 ml unit)
- Filling time:
- 30 s - 999 s (time according to the cylinder volume)
- 30 s - 999 s (time according to the cylinder volume)
- 30 s - 999 s (time according to the cylinder volume)
- 30 s - 999 s (time according to the cylinder volume)
- Burette resolution:
- 8000 steps
- 8000 steps
- 8000 steps
- 8000 steps
- Connections:
- 1× USB-A, 1× USB-B, 2× RS-232-C
- 1× USB-A, 1× USB-B, 2× RS-232-C
- 1× USB-A, 1× USB-B, 2× RS-232-C
- 1× USB-A, 1× USB-B, 2× RS 232-C
- Power supply:
- 100 - 240 V, 50/60 Hz
- 100 - 240 V, 50/60 Hz
- 100 - 240 V, 50/60 Hz
- 100 - 240 V, 50/60 Hz
- Operating temperature:
- 10...40 °C
- 10...40 °C
- 10...40 °C
- 10...40 °C
- Compliance:
- EMC: 2004/108/EG; safety EG Directive 2006/95
- EMC: 2004/108/EG; safety EG Directive 2006/95
- EMC: 2004/108/EG; safety EG Directive 2006/95
- EMC: 2004/108/EG; safety EG Directive 2006/95
- W×D×H:
- 135×205×310 mm
- 135×205×310 mm
- 135×205×310 mm
- 135×205×310 mm
- Weight:
- 2 kg (without stirrer)
- 2 kg (without stirrer)
- 2 kg (without stirrer)