75 Results for: "Sensidyne"
Gilian® GilAir-3 Air Sampling Pumps, Sensidyne Inc
Supplier: Sensidyne
Constant flow air sampling pump features clear external filter housing allows an immediate visual inspection of filter’s condition. The flow fault indicator lights up if unit operates outside ±5% of set flow rate. Battery test indicator lights up when battery can provide a minimum of 8 hours of operation over operating range.
Expand 5 Items
Compressed Breathing Air Analysis Kit, Sensidyne®
Supplier: Sensidyne
Convenient, economical system tests the quality of compressed breathing air
Expand 6 Items
Gas Detector Tubes for Ethyl Alcohol, Sensidyne
Supplier: Sensidyne
Gas detector tubes are used for detection of airbourne gases and vapors.
Expand 1 Items
![313376_260x190.jpg](https://occapi.avantorsciences.com/medias/313376-260x190.jpg?context=bWFzdGVyfGltYWdlc3w5NDQ1fGltYWdlL2pwZWd8YURReUwyZzFZUzg1TnpBMk1ETTBOekkwT0RrMEx6TXhNek0zTmw4eU5qQjRNVGt3TG1wd1p3fGY0MjhiMmY1ZGJjNTY3NDdlZDk5ZjMwMGEyYTdmYjNkY2IyNWE2ZmI1MTg2YTM4MjE0MTY4MmNiYjVmNTViMTE)
Now Available: Our latest edition of elements!
Unlock innovation! Packed with products from both our leading suppliers and our exclusive Avantor® brands.
Gas Detector Tubes for Acetone, Sensidyne
Supplier: Sensidyne
Gas detector tubes are used for detection of airbourne gases and vapors.
Expand 1 Items
Phosgene Colorimetric Gas Detector Tubes, Sensidyne
Supplier: Sensidyne
Phosgene colorimetric gas detector tubes for detection of airborne gases and vapors with detector tube pump and an antibacterial grip.
Expand 1 Items
Gas Detector Tubes for Ethyl Ether, Sensidyne
Supplier: Sensidyne
Colorimetric gas detector tubes are used for detection of airbourne gases and vapors.
Expand 1 Items
Gas Detection Pump Kit and Hydrogen Sulfide Detection Tubes, Sensidyne®
Supplier: Sensidyne
This portable unit is lightweight, rugged, and capable of on-the-spot, precise detection of numerous gases and vapors
Expand 6 Items
Colorimetric Gas Detector Tubes, Sensidyne
Supplier: Sensidyne
Detector tubes for detection of oxygen-non-heating type.
Expand 1 Items
Gas Detector Tubes for Carbon Monoxide, Sensidyne
Supplier: Sensidyne
Gas detector tubes are used for detection of airbourne gases and vapors.
Expand 1 Items
Accessories for Air Flow Indicator Kit, Sensidyne
Supplier: Sensidyne
Performs fast, safe, and reliable qualitative respirator fit testing. An accessory for Respirator Fit Test kits.
Expand 1 Items
Nitric Acid (LR) Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 1-20ppm.
Expand 1 Items
Xylene Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 5-1000ppm.
Expand 1 Items
Acetone Gas Detector Tube
Supplier: Sensidyne
For use with gas detection systems. Range: 100 to 5000ppm. Detectable limit: 20ppm (200mL).
Expand 1 Items
Sensidyne #138U Butyl Acetate Detector Tube
Supplier: Sensidyne
Sensidyne-Kitagawa detector tubes are single stroke detector tubes for easy, low-cost spot detection of a wide range of hazardous gases and vapors. Chemical: Butyl Acetate. Range: 10-400ppm.
Expand 1 Items
Nitric Oxide Gas Detector Tube
Supplier: Sensidyne
For use with gas detection systems. Range: 0.5 to 30ppm. Detectable limit: 0.2ppm (100mL).
Expand 1 Items
Vinyl Chloride (LR) Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 0.1-12ppm.
Expand 1 Items
Hydrogen Cyanide (LR) Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 0.5-100ppm.
Expand 1 Items
Phosphine Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 0.25-20ppm.
Expand 1 Items
HYDRAZINE DETECTOR TUBES PK10
Supplier: Sensidyne
HYDRAZINE DETECTOR TUBES PK10
Expand 1 Items
Sulfur Dioxide Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 1-60ppm.
Expand 1 Items
Ethyl Acetate (LR) Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 20-1000ppm.
Expand 1 Items
Isopropyl Alcohol Detector Tubes
Supplier: Sensidyne
Isopropyl Alcohol, 20-1200ppm. Pack of 10.
Expand 1 Items
Diethyl/Trimethyl Amine Detector Tubes
Supplier: Sensidyne
Diethyl/Trimethyl Amine, 1-10ppm. Pack of 10.
Expand 1 Items
2-Ethoxyethanol Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 5-500ppm.
Expand 1 Items
Methylene Chloride Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 10-1000ppm.
Expand 1 Items
Acetic Acid Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 1-50ppm.
Expand 1 Items
Water Vapor Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 1.7-33.8mg/M3.
Expand 1 Items
Methyl Alcohol (LR), (XLR) Detector Tube
Supplier: Sensidyne
Quantitative detection. For use with Sensidyne* Gas Detection System (13502-550). Fine-grain silica gel, activated alumina, or other absorbants in sealed glass. Reagent color change and length of stain indicators. Range: 20-1000ppm.