Order Entry
Canada
ContactUsLinkComponent
Orion™ Lab Star EC112 Conductivity/Salinity/TDS Bench Meters, Thermo Scientific
Certificats
undefined
Orion™ Lab Star EC112 Conductivity/Salinity/TDS Bench Meters, Thermo Scientific

Spécifications

  • Catalog No:
  • 76557-426
  • 76557-418
  • Conductivity range:
  • 0.00 μS/cm - 500.0 mS/cm
  • 0.00 μS/cm - 500.0 mS/cm
  • Conductivity resolution:
  • 0.01, 0.1, 1 μS/cm, 0.01, 0.1 mS/cm
  • 0.01, 0.1, 1 μS/cm, 0.01, 0.1 mS/cm
  • Conductivity accuracy:
  • ±0.5% reading ±1 LSD (relative)
  • ±0.5% reading ±1 LSD (relative)
  • Conductivity calibration:
  • 1 - 5 points (Automatic standard recognition with manual entry option)
  • 1 - 5 points (Automatic standard recognition with manual entry option)
  • Conductivity reference temperature:
  • 15.0, 20.0, 25.0 or 30.0 °C
  • 15.0, 20.0, 25.0 or 30.0 °C
  • Salinity range:
  • 0.00 - 80.0 ppt, 0.00 - 42.0 PSU
  • 0.00 - 80.0 ppt, 0.00 - 42.0 PSU
  • Salinity resolution:
  • 0.01, 0.1 ppt, 0.01, 0.1 PSU [Natural Seawater (ppt) or Practical Salinity (PSU) modes]
  • 0.01, 0.1 ppt, 0.01, 0.1 PSU [Natural Seawater (ppt) or Practical Salinity (PSU) modes]
  • Salinity accuracy:
  • ±0.5% reading ±1 LSD (relative)
  • ±0.5% reading ±1 LSD (relative)
  • TDS range:
  • 0.00 ppm - 500.0 ppt (1.00 factor)
  • 0.00 ppm - 500.0 ppt (1.00 factor)
  • TDS resolution:
  • 0.01, 0.1, 1 ppm, 0.01, 0.1 ppt
  • 0.01, 0.1, 1 ppm, 0.01, 0.1 ppt
  • TDS accuracy:
  • ±0.5% reading ±1 LSD (relative)
  • ±0.5% reading ±1 LSD (relative)
  • TDS conversion factor:
  • 0.40 - 1.00
  • 0.40 - 1.00
  • Temperature range:
  • −5.0...+105.0 °C, 23.0...221.0 °F
  • −5.0...+105.0 °C, 23.0...221.0 °F
  • Temperature resolution:
  • 0.1 °C, 0.1 °F
  • 0.1 °C, 0.1 °F
  • Temperature accuracy:
  • ±0.3 °C, ±0.5 °F (relative)
  • ±0.3 °C, ±0.5 °F (relative)
  • Temperature calibration:
  • 1 point
  • 1 point
  • Temperature compensation:
  • Linear (0 - 10%/°C) or off
  • Linear (0 - 10%/°C) or off
  • Data logging capacity:
  • 500 sets with time and date
  • 500 sets with time and date
  • Outputs:
  • Computer or printer
  • Computer or printer
  • Input:
  • 8-pin MiniDIN
  • 8-pin MiniDIN
  • Power supply:
  • 100 - 240 V 50/60 Hz, 9 DC adapter, 1.3 A
  • 100 - 240 V 50/60 Hz, 9 DC adapter, 1.3 A
  • Calibration points:
  • 1 point (salinity), 1 - 5 points (TDS )
  • 1 point (salinity), 1 - 5 points (TDS )
  • Calibration:
  • Active conductivity, salinity, TDS, temperature with time and date (calibration log)
  • Active conductivity, salinity, TDS, temperature with time and date (calibration log)
  • Display:
  • 5" backlit LCD
  • 5" backlit LCD
  • Alarm:
  • 1 - 168 h or off (calibration)
  • 1 - 168 h or off (calibration)
  • IP rating:
  • IP-54
  • IP-54
  • Memory:
  • Non-volatile
  • Non-volatile
  • W×D×H:
  • 187.2×155.2×61.7 mm (7.37×6.11×2.43")
  • 155.2×187.2×61.7 mm (6.11×7.37×2.43")
  • Weight:
  • 700 g (1.54 lbs.)
  • 700 g (1.54 lbs.)