68337 Results for: "L-Pyroglutamic acid pentachlorobiphenyl ester"
Spinner Turbine, for Bruker Systems, Room Temperature Use, Color: White, Causes less probe insert damage by better insert sample control, Tachometer strip now with foil protection for improved life span, Can be mixed with originals during sample changer operation, Dimension: 3mm
Supplier: SP Industries
Spinner Turbine, for Bruker Systems, Room Temperature Use, Color: White, Causes less probe insert damage by better insert sample control, Tachometer strip now with foil protection for improved life span, Can be mixed with originals during sample changer operation, Dimension: 3mm
Expand 1 Items
D-dimer known as fibrin degradation product, presented in blood after blood clot degraded by fibrinolysis. Its concentration in blood increases when deep venous thrombos (DVT), pulmonary embolism (PE) or disseminated intravascular coagulation (DIC) happens. It serves as useful maker fo, Size: 100mg
Supplier: Genscript
D-dimer known as fibrin degradation product, presented in blood after blood clot degraded by fibrinolysis. Its concentration in blood increases when deep venous thrombos (DVT), pulmonary embolism (PE) or disseminated intravascular coagulation (DIC) happens. It serves as useful maker fo, Size: 100mg
Expand 1 Items
Holey Thick Carbon Grid, Copper Only, An ultra-flat, for TEM, Manufactured without plastics, it is clean and without residue, Ultra-flat for better particle dispersion and more uniform ice thickness, Hole Size: 2.0 um, Hole spacing: 1.0 um, TEM Mesh: 300
Supplier: ELECTRON MICROSCOPY SCIENCE
Holey Thick Carbon Grid, Copper Only, An ultra-flat, for TEM, Manufactured without plastics, it is clean and without residue, Ultra-flat for better particle dispersion and more uniform ice thickness, Hole Size: 2.0 um, Hole spacing: 1.0 um, TEM Mesh: 300
Expand 1 Items
![313376_260x190.jpg](https://occapi.avantorsciences.com/medias/313376-260x190.jpg?context=bWFzdGVyfGltYWdlc3w5NDQ1fGltYWdlL2pwZWd8YURReUwyZzFZUzg1TnpBMk1ETTBOekkwT0RrMEx6TXhNek0zTmw4eU5qQjRNVGt3TG1wd1p3fGY0MjhiMmY1ZGJjNTY3NDdlZDk5ZjMwMGEyYTdmYjNkY2IyNWE2ZmI1MTg2YTM4MjE0MTY4MmNiYjVmNTViMTE)
Now Available: Our latest edition of elements!
Unlock innovation! Packed with products from both our leading suppliers and our exclusive Avantor® brands.
Holey Thick Carbon Grid, Copper Only, An ultra-flat, for TEM, Manufactured without plastics, it is clean and without residue, Ultra-flat for better particle dispersion and more uniform ice thickness, Hole Size: 1.2 um, Hole spacing: 1.3 um, TEM Mesh: 300
Supplier: ELECTRON MICROSCOPY SCIENCE
Holey Thick Carbon Grid, Copper Only, An ultra-flat, for TEM, Manufactured without plastics, it is clean and without residue, Ultra-flat for better particle dispersion and more uniform ice thickness, Hole Size: 1.2 um, Hole spacing: 1.3 um, TEM Mesh: 300
Expand 1 Items
Holey Thick Carbon Grid, Copper Only, An ultra-flat, for TEM, Manufactured without plastics, it is clean and without residue, Ultra-flat for better particle dispersion and more uniform ice thickness, Hole Size: 1.2 um, Hole spacing: 1.3 um, TEM Mesh: 300
Supplier: ELECTRON MICROSCOPY SCIENCE
Holey Thick Carbon Grid, Copper Only, An ultra-flat, for TEM, Manufactured without plastics, it is clean and without residue, Ultra-flat for better particle dispersion and more uniform ice thickness, Hole Size: 1.2 um, Hole spacing: 1.3 um, TEM Mesh: 300
Expand 1 Items
O-Ring, For Spinner STV-5 & V-PEEK-5, Color: Red, Causes less probe insert damage by better insert sample control, Tachometer strip now with foil protection for improved life span, Longer upper barrel stabilizer easily identified by 3mm yellow band, Susceptibility matched to the originals
Supplier: SP Industries
O-Ring, For Spinner STV-5 & V-PEEK-5, Color: Red, Causes less probe insert damage by better insert sample control, Tachometer strip now with foil protection for improved life span, Longer upper barrel stabilizer easily identified by 3mm yellow band, Susceptibility matched to the originals
Expand 1 Items
PG 8596, Dispensing cabinet, For process chemicals and dispenser modules, 2 removable drawers for 3 x 5 l canisters each, Internal dimensions H 285-690, W 250, D 425-555 mm, Each level 2 holding options per level for dispenser modules, Drip tray facilitates better residual emptying of the canister
Supplier: Miele
PG 8596, Dispensing cabinet, For process chemicals and dispenser modules, 2 removable drawers for 3 x 5 l canisters each, Internal dimensions H 285-690, W 250, D 425-555 mm, Each level 2 holding options per level for dispenser modules, Drip tray facilitates better residual emptying of the canister
Expand 1 Items
D-dimer known as fibrin degradation product, presented in blood after blood clot degraded by fibrinolysis. Its concentration in blood increases when deep venous thrombos (DVT), pulmonary embolism (PE) or disseminated intravascular coagulation (DIC) happens. It serves as useful maker fo, Size: 1mg
Supplier: Genscript
D-dimer known as fibrin degradation product, presented in blood after blood clot degraded by fibrinolysis. Its concentration in blood increases when deep venous thrombos (DVT), pulmonary embolism (PE) or disseminated intravascular coagulation (DIC) happens. It serves as useful maker fo, Size: 1mg
Expand 1 Items
Spike RBD Polyclonal antibody, Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2, Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within the center region of SARS-CoV-2 Spike (S1), Synonyms: 2019-nCoV Spike, SARS-CoV-2 Spike, Size: 100ul
Supplier: Genetex
Spike RBD Polyclonal antibody, Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2, Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within the center region of SARS-CoV-2 Spike (S1), Synonyms: 2019-nCoV Spike, SARS-CoV-2 Spike, Size: 100ul
Expand 1 Items
Heater For Fractron 100, 1 zone of 18 kW of heating capacity. Pump Capacity: 1 HP, 18 GPM 30 PSI. 230 V, 1/8 DIN Controller - 4-20MA/0--10V, Zone 1. CE Certification available. Requires two 55-gal drums of Paratherm NF oil (Not included)
Supplier: United Science
Heater For Fractron 100, 1 zone of 18 kW of heating capacity. Pump Capacity: 1 HP, 18 GPM 30 PSI. 230 V, 1/8 DIN Controller - 4-20MA/0--10V, Zone 1. CE Certification available. Requires two 55-gal drums of Paratherm NF oil (Not included)
Expand 1 Items
Cartridge, Nominal length: 5in, .2um Pleated PTFE membrane, SOE Flat Top/222 end cap with external silicone o-rings, sterile gas filters combine proven depth filter technology and a pleated construction to provide retention down to 0.01 micron in gas.
Supplier: PARKER HANNIFIN TE
Cartridge, Nominal length: 5in, .2um Pleated PTFE membrane, SOE Flat Top/222 end cap with external silicone o-rings, sterile gas filters combine proven depth filter technology and a pleated construction to provide retention down to 0.01 micron in gas.
Expand 1 Items
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 16mil thick, 10in port, Ambidextrous, Size: 11
Supplier: Ansell Healthcare
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 16mil thick, 10in port, Ambidextrous, Size: 11
Expand 1 Items
Mask, Double-Seal Arching, White, pinch point bar on nose, chin and middle bar for comfort, breathability, better protection. Hypoallergenic for sensitive skin, softest ear loops, ultra-high filtration, PFE 99.7%, at 0.1micron, BFE 99.5%, very breathable. Latex free. ASTM Level 2 standard, 120mmHg
Supplier: CANCER DIAGNOSTICS, INC.
Mask, Double-Seal Arching, White, pinch point bar on nose, chin and middle bar for comfort, breathability, better protection. Hypoallergenic for sensitive skin, softest ear loops, ultra-high filtration, PFE 99.7%, at 0.1micron, BFE 99.5%, very breathable. Latex free. ASTM Level 2 standard, 120mmHg
Expand 1 Items
Spike S2 Monoclonal antibody, Clone: [HL237], Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2 (COVID-19), Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within center region of SARS-CoV-2 Spike, Synonyms: 2019-nCoV Spike, Size: 100ul
Supplier: Genetex
Spike S2 Monoclonal antibody, Clone: [HL237], Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2 (COVID-19), Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within center region of SARS-CoV-2 Spike, Synonyms: 2019-nCoV Spike, Size: 100ul
Expand 1 Items
Polymeric SPE 96-Well Plate, WCX, 30mg, Analyte: Strong bases, Silica-free, bonded polymeric material, High surface area, Stable over a wide pH range (0 -14), Water-wettable, No flow-rate dependence-maintains retention and capacity after conditioning, for high throughput and automation
Supplier: Restek
Polymeric SPE 96-Well Plate, WCX, 30mg, Analyte: Strong bases, Silica-free, bonded polymeric material, High surface area, Stable over a wide pH range (0 -14), Water-wettable, No flow-rate dependence-maintains retention and capacity after conditioning, for high throughput and automation
Expand 1 Items
Polymeric SPE 96-Well Plate, WCX, 10mg, Analyte: Strong bases, Silica-free, bonded polymeric material, High surface area, Stable over a wide pH range (0 -14), Water-wettable, No flow-rate dependence-maintains retention and capacity after conditioning, for high throughput and automation
Supplier: Restek
Polymeric SPE 96-Well Plate, WCX, 10mg, Analyte: Strong bases, Silica-free, bonded polymeric material, High surface area, Stable over a wide pH range (0 -14), Water-wettable, No flow-rate dependence-maintains retention and capacity after conditioning, for high throughput and automation
Expand 1 Items
Polymeric SPE 96-Well Plate, MCX, 30mg, Analyte: Bases, Silica-free, bonded polymeric material, High surface area, Stable over a wide pH range (0 -14), Water-wettable, No flow-rate dependence-maintains retention and capacity after conditioning, for high throughput and automation
Supplier: Restek
Polymeric SPE 96-Well Plate, MCX, 30mg, Analyte: Bases, Silica-free, bonded polymeric material, High surface area, Stable over a wide pH range (0 -14), Water-wettable, No flow-rate dependence-maintains retention and capacity after conditioning, for high throughput and automation
Expand 1 Items
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 24mil thick, 12in port, Ambidextrous, Size: 9.5
Supplier: Ansell Healthcare
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 24mil thick, 12in port, Ambidextrous, Size: 9.5
Expand 1 Items
O-Ring, for Spinner, Uni-Finger, Red Viton, Causes less probe insert damage by better insert sample control, Variable temperature operation from -150 deg C to +200 deg C, Tachometer strip now with foil protection for improved life span, Weight compatible with room temperature spinners
Supplier: SP Industries
O-Ring, for Spinner, Uni-Finger, Red Viton, Causes less probe insert damage by better insert sample control, Variable temperature operation from -150 deg C to +200 deg C, Tachometer strip now with foil protection for improved life span, Weight compatible with room temperature spinners
Expand 1 Items
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 24mil thick, 8in port, Ambidextrous, Size: 11
Supplier: Ansell Healthcare
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 24mil thick, 8in port, Ambidextrous, Size: 11
Expand 1 Items
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 16mil thick, 10in port, Ambidextrous, Size: 9.5
Supplier: Ansell Healthcare
EPDM Isolator Gloves, non-sterile, Comfortable and dexterous with great tactile sensitivity, Resistant against hydrogen peroxide solutions and common disinfecting chemicals, Resists aging from exposure to oxygen, UV rays and ozone,Size: 32in long, 16mil thick, 10in port, Ambidextrous, Size: 9.5
Expand 1 Items
Spike RBD Monoclonal antibody, Clone: [HL257], Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2 (COVID-19), Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within the center region of SARS-CoV-2 Spike (S1), Synonyms: 2019-nCoV Spike, Size: 100ul
Supplier: Genetex
Spike RBD Monoclonal antibody, Clone: [HL257], Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2 (COVID-19), Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within the center region of SARS-CoV-2 Spike (S1), Synonyms: 2019-nCoV Spike, Size: 100ul
Expand 1 Items
Spike S2 / S2' Polyclonal antibody, Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2, Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within the center region of SARS-CoV-2 Spike (S2), Synonyms: 2019-nCoV Spike, SARS-CoV-2 Spike, Size: 100ul
Supplier: Genetex
Spike S2 / S2' Polyclonal antibody, Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2, Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within the center region of SARS-CoV-2 Spike (S2), Synonyms: 2019-nCoV Spike, SARS-CoV-2 Spike, Size: 100ul
Expand 1 Items
TER-119 Monoclonal antibody, Clone: TER-119, Host: Rat, Species reactivity: Rat, Isotype: IgG2b, Kappa, Format: APC-Cyanine7, Application: Flow Cytometry, TER-119 antigen is not expressed at either BFU-E or CFU-E stages, i.e. Prior to the pro-erythroblast stage, Size: 25ug
Supplier: Tonbo Biosciences
TER-119 Monoclonal antibody, Clone: TER-119, Host: Rat, Species reactivity: Rat, Isotype: IgG2b, Kappa, Format: APC-Cyanine7, Application: Flow Cytometry, TER-119 antigen is not expressed at either BFU-E or CFU-E stages, i.e. Prior to the pro-erythroblast stage, Size: 25ug
Expand 1 Items
RC 5 basic, Temperature Control, Powerful recirculating chiller, designed for external cooling applications up to -30 deg C, Speed-controlled refrigeration system with 1400 W cooling capacity (20C), Natural thermofluid R290, extended operating temperature range until 80C, Digital level indicator
Supplier: IKA Works
RC 5 basic, Temperature Control, Powerful recirculating chiller, designed for external cooling applications up to -30 deg C, Speed-controlled refrigeration system with 1400 W cooling capacity (20C), Natural thermofluid R290, extended operating temperature range until 80C, Digital level indicator
Expand 1 Items
Spinner Turbine, Material: PEEK, Cost effective compared to the full VT version for sample changers, Variable Temperature -150 to +200deg C with 5 mm PEEK exchangeable fingers, Can also be used for spinning experiments, Includes high temperature external O-rings at the top & bottom, Dimension: 3-5mm
Supplier: SP Industries
Spinner Turbine, Material: PEEK, Cost effective compared to the full VT version for sample changers, Variable Temperature -150 to +200deg C with 5 mm PEEK exchangeable fingers, Can also be used for spinning experiments, Includes high temperature external O-rings at the top & bottom, Dimension: 3-5mm
Expand 1 Items
RdRp (nsp12) Polyclonal antibody, Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2 (COVID-19), Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within center region of SARS-CoV-2 RdRp (nsp12), Synonyms: 2019-nCoV RdRp, Application: WB, Size: 100ul
Supplier: Genetex
RdRp (nsp12) Polyclonal antibody, Host: Rabbit, Reactivity: SARS Coronavirus 2/SARS-CoV-2 (COVID-19), Isotype: IgG, Immunogen: Carrier-protein conjugated synthetic peptide encompassing a sequence within center region of SARS-CoV-2 RdRp (nsp12), Synonyms: 2019-nCoV RdRp, Application: WB, Size: 100ul
Expand 1 Items
Vial, 2.0mL, Amber, Silanized, Large Opening, 12x32mm, 9mm Thread. With a 40% larger opening, these vials are specifically designed to work in robotic arm auto samplers. They also incorporate the unique Step Vial design that precisely centers a limited volume insert in the neck of the vial. Available with graduated marking spots, and silanized.
Supplier: Chemglass
Vial, 2.0mL, Amber, Silanized, Large Opening, 12x32mm, 9mm Thread. With a 40% larger opening, these vials are specifically designed to work in robotic arm auto samplers. They also incorporate the unique Step Vial design that precisely centers a limited volume insert in the neck of the vial. Available with graduated marking spots, and silanized.
Expand 1 Items
Vial, 2.0mL, Amber, Large Opening, 12x32mm, 9mm Thread. With a 40% larger opening, these vials are specifically designed to work in robotic arm auto samplers. They also incorporate the unique Step Vial design that precisely centers a limited volume insert in the neck of the vial. Available with graduated marking spots, and silanized.
Supplier: Chemglass
Vial, 2.0mL, Amber, Large Opening, 12x32mm, 9mm Thread. With a 40% larger opening, these vials are specifically designed to work in robotic arm auto samplers. They also incorporate the unique Step Vial design that precisely centers a limited volume insert in the neck of the vial. Available with graduated marking spots, and silanized.
Expand 1 Items
TER-119 Monoclonal antibody, Clone: TER-119, Host: Rat, Species reactivity: Rat, Isotype: IgG2b, Kappa, Format: APC-Cyanine7, Application: Flow Cytometry, TER-119 antigen is not expressed at either BFU-E or CFU-E stages, i.e. Prior to the pro-erythroblast stage, Size: 100 ug
Supplier: Tonbo Biosciences
TER-119 Monoclonal antibody, Clone: TER-119, Host: Rat, Species reactivity: Rat, Isotype: IgG2b, Kappa, Format: APC-Cyanine7, Application: Flow Cytometry, TER-119 antigen is not expressed at either BFU-E or CFU-E stages, i.e. Prior to the pro-erythroblast stage, Size: 100 ug