You searched for: Hollow Cathode Lamps
Designed to achieve spectral line source requirements, the hollow cathode lamps permit the intense emission of resonance lines, narrow line width for maximum sensitivity and linearity, minimal spectral interference from continuum emission, and rapid warm-up to produce stable, long-term light emission. Used primarily in physics and chemistry applications, the light sources support atomic absorption spectrometers and lasers for frequency tuning. Operating without noise, the hollow cathode lamps feature hermetically sealed glass that fills cleanly with gas.
Lumina™ Multi-Element Hollow Cathode Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
Series N30502XX Lumina™ 50 mm (2") diameter multi-element lamps are designed to be used with PerkinElmer PinAAcle™ and AAnalyst™ Atomic Absorption spectrometer series of instruments.
Expand 1 Items
Selenium (Se) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 Electrodeless Discharge Lamps (EDLs) provide the optimized spectral output needed to get the maximum performance from PerkinElmer® Atomic Absorption (AA) spectrometers.
Expand 1 Items
Thallium (Tl) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 Electrodeless Discharge Lamps (EDLs) provide the optimized spectral output needed to get the maximum performance from PerkinElmer® Atomic Absorption (AA) spectrometers.
Expand 1 Items
![304503sfnew.jpg](https://occapi.avantorsciences.com/medias/304503sfnew.jpg?context=bWFzdGVyfGltYWdlc3wxMTYxOXxpbWFnZS9qcGVnfGFHTTJMMmhpWVM4NU56QTRPRFEzTXpNek5EQTJMek13TkRVd00zTm1ibVYzTG1wd1p3fGM3NjFjYjg1NDEwNzZmNTMyYWIyMTZiMmQ3MmRkNTY0NjQ1ZWUzZDRjMTk5NjE2MTI2MGRmMWUwMThkZTAzNWE)
FOCUS: SAFETY - OUT NOW!
Let’s enhance safety by considering personalized protection equipment (PPE) solutions tailored to your team, processes, and products.
Antimony (Sb) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 Electrodeless Discharge Lamp for the detection of elemental Antimony (Sb). This lamp provides the optimized spectral output needed to get the maximum performance from PerkinElmer® Atomic Absorption spectrometers.
Expand 1 Items
Arsenic (As) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 electrodeless discharge lamps (EDLs) provide the optimized spectral output needed to get the maximum performance from PerkinElmer® Atomic Absorption spectrometers.
Expand 1 Items
Cadmium (Cd) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 Electrodeless Discharge Lamps (EDLs) provide the optimized spectral output needed to get the maximum performance from PerkinElmer Atomic Absorption spectrometers.
Expand 1 Items
Mercury (Hg) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 electrodeless discharge lamps (EDLs) provide the optimized spectral output needed to get the maximum performance from PerkinElmer Atomic Absorption spectrometers.
Expand 1 Items
Cesium (Cs) System 2 Electrodeless Discharge Lamp, PerkinElmer
Supplier: PERKINELMER SCIENTIFIC CANADA ULC
System 2 Electrodeless Discharge Lamps (EDLs) provide the optimized spectral output needed to get the maximum performance from PerkinElmer® Atomic Absorption (AA) spectrometers.
Expand 1 Items
Hollow Cathode Lamps to Suit PerkinElmer Systems, Photron
Supplier: PHOTRON CA
Photron's P900 (51mm or 2.0” Diameter) series is designed for direct use in AAS systems manufactured by PerkinElmer.
Expand 5 Items
Hollow Cathode Lamps to Suit All AAS Systems, Photron
Supplier: PHOTRON CA
Hollow cathode lamps produced by Photron are designed and manufactured to achieve all of the following fundamental requirements for a spectral line source: Intense emission of resonance (ground state derived) lines. Narrow line width, for maximum sensitivity and linearity. Minimal spectral interference from continuum emission, present in the cathode. Rapid warm up to produce stable long term light emission. Noise free operation. Long running life and a 5 year shelf life. Cathode materials and geometry achieve a combination of spectral purity and a suitable sputtering rate. (A high sputtering rate will give high intensity at the expense of lamp life, sensitivity and linearity).
Expand 39 Items
Denka M3 LaB6 Cathode, Electron Microscopy Sciences
Supplier: Electron Microscopy Sciences
Lanthanum Hexaboride is the optimum cathode material for use in SEM, TEM, X-Ray Microanalysis, and Electron Beam Lithography.
Expand 4 Items
Lanthanum Hexaboride (LaB6) Cathodes, Electron Microscopy Sciences
Supplier: Electron Microscopy Sciences
The new improved Kimball Physics Model ES-423E (Extended Life) LaB6 Cathode is a high performance, resistively heated, thermionic electron source. The improvement stability of the LaB6 crystal, results in less exposure of LaB6, which reduces Wehnelt aperture contamination. It is for use in Scanning Electron Microscopes, Transmission Electron Microscopes, Electronlithography Systems, and X-Ray Sources.